4-Way Hydrant Valve
This valve allows you to provide water to the fire at hydrant pressure, while waiting for a second pumper to hook up and increase flow and pressure.
Flow efficient 3 1⁄2" waterway
75 psi maximum pressure differential during changeover
300 psi maximum operating pressure
1000 gpm maximum flow when changing the ball position
HOW IT WORKS:
Step 1 - Attach the 4-Way Hydrant Valve to the hydrant and forward lay to the engine at fire scene.
Step 2 – Attach a hose from the 4-Way Hydrant Valve to the intake on the engine at the hydrant.
Step 3 – Attach a hose from the discharge on the engine at hydrant to the 4-Way Hydrant Valve inlet. Establish recirculating flow at hydrant pressure.
Step 4 – Rotate the handwheel on top of the 4 way Hydrant Valve to introduce pressurized flow from the engine at the hydrant to the engine at the fire scene. Increase pressure on the pumper to increase flow as required.